Sedelon Valve Co.,Ltd is a professional fugitive emission gate valve company with productive factory, we are the best fugitive emission gate valve manufacturer and supplier from China.
Application
Face to Face Dimensions:ANSI B16.10
Flange end Dimension :ANSI B16.5
Butt Welded Dimensions:ANSI B16.25
Design and Manufacture:API 600
Pressure Test:API 598
Fugitve Emission Test :ISO 15848-1:2006
Fugitve Emission Test Certificate Number :214169A
Main material: WCB 、WC6 、WC9 、CF8、 CF8M、 CF3、 CF3M 、CN7M、LC1、LC2、LC3、LCB、LCC、Monel、 20# Alloys、4A、5A、C95800、C95500, ect.
Class150 Fugitive Emission Gate Valve
NPS |
in |
2 |
2 1/2 |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
14 |
16 |
18 |
20 |
24 |
d |
mm |
51 |
64 |
76 |
102 |
127 |
152 |
203 |
254 |
305 |
337 |
387 |
438 |
489 |
591 |
L(RF) |
mm |
178 |
190 |
203 |
229 |
254 |
267 |
292 |
330 |
356 |
381 |
406 |
432 |
457 |
508 |
L(BW) |
mm |
216 |
241 |
283 |
305 |
381 |
403 |
419 |
457 |
502 |
572 |
610 |
660 |
711 |
813 |
L(RTJ) |
mm |
191 |
203 |
216 |
241 |
267 |
279 |
305 |
343 |
368 |
394 |
419 |
445 |
470 |
521 |
d1 |
mm |
92 |
105 |
127 |
157 |
186 |
216 |
270 |
324 |
381 |
413 |
470 |
533 |
584 |
692 |
d2 |
mm |
120.5 |
139.5 |
152.5 |
190.5 |
216 |
241.5 |
298.5 |
362 |
432 |
476 |
540 |
578 |
635 |
749.5 |
D |
mm |
152 |
178 |
190 |
229 |
254 |
279 |
343 |
406 |
483 |
533 |
597 |
635 |
699 |
813 |
b |
mm |
16 |
18 |
19 |
24 |
24 |
26 |
29 |
31 |
32 |
35 |
37 |
40 |
43 |
48 |
n-Фd |
mm |
4-19 |
4-19 |
4-19 |
8-19 |
8-22 |
8-22 |
8-22 |
12-25 |
12-25 |
12-29 |
16-29 |
16-32 |
20-32 |
20-35 |
H |
mm |
400 |
435 |
515 |
595 |
725 |
780 |
975 |
1150 |
1380 |
1545 |
1733 |
1915 |
2122 |
2520 |
H1 |
mm |
|
|
|
|
|
820 |
1020 |
1200 |
1430 |
1580 |
1780 |
1990 |
2220 |
2600 |
W |
mm |
200 |
200 |
250 |
280 |
280 |
300 |
350 |
400 |
450 |
500 |
500 |
500 |
600 |
600 |
W1 |
mm |
|
|
|
|
|
310 |
310 |
310 |
310 |
310 |
460 |
460 |
460 |
460 |
Class300 Fugitive Emission Gate Valve
NPS |
in |
2 |
2 1/2 |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
14 |
16 |
18 |
20 |
24 |
d |
mm |
51 |
64 |
76 |
102 |
127 |
152 |
203 |
254 |
305 |
337 |
387 |
432 |
483 |
584 |
L(RF) |
mm |
216 |
241 |
283 |
305 |
381 |
403 |
419 |
457 |
502 |
762 |
838 |
914 |
991 |
1143 |
L(BW) |
mm |
216 |
241 |
283 |
305 |
381 |
403 |
419 |
457 |
502 |
762 |
838 |
914 |
991 |
1143 |
L(RTJ) |
mm |
232 |
257 |
298 |
321 |
397 |
419 |
435 |
473 |
518 |
778 |
854 |
930 |
1010 |
1165 |
d1 |
mm |
92 |
105 |
127 |
157 |
186 |
216 |
270 |
324 |
381 |
413 |
470 |
533 |
584 |
692 |
d2 |
mm |
127 |
149 |
168.5 |
200 |
235 |
270 |
330 |
387.5 |
451 |
514.5 |
571.5 |
628.5 |
686 |
813 |
D |
mm |
165 |
190 |
210 |
254 |
279 |
318 |
381 |
445 |
521 |
584 |
648 |
711 |
775 |
914 |
b |
mm |
23 |
26 |
29 |
32 |
35 |
37 |
42 |
48 |
51 |
54 |
58 |
61 |
64 |
70 |
n-Фd |
mm |
8-19 |
8-22 |
8-22 |
8-22 |
8-22 |
12-22 |
12-25 |
16-29 |
16-32 |
20-32 |
20-35 |
24-35 |
24-35 |
24-41 |
H |
mm |
420 |
446 |
537 |
619 |
722 |
806 |
1000 |
1240 |
1425 |
1585 |
1790 |
1960 |
2158 |
2576 |
H1 |
mm |
|
|
|
650 |
750 |
835 |
1030 |
1280 |
1460 |
1620 |
1830 |
2000 |
2220 |
2620 |
W |
mm |
200 |
200 |
250 |
280 |
300 |
350 |
400 |
450 |
500 |
500 |
600 |
650 |
750 |
900 |
W1 |
mm |
|
|
|
310 |
310 |
310 |
310 |
310 |
310 |
460 |
460 |
460 |
460 |
600 |
Class600 Fugitive Emission Gate Valve
NPS |
in |
2 |
2 1/2 |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
14 |
16 |
18 |
20 |
24 |
d |
mm |
51 |
64 |
76 |
102 |
127 |
152 |
200 |
248 |
298 |
327 |
375 |
419 |
464 |
559 |
L(RF) |
mm |
292 |
330 |
356 |
432 |
508 |
559 |
660 |
787 |
838 |
889 |
991 |
1092 |
1194 |
1397 |
L(BW) |
mm |
292 |
330 |
356 |
432 |
508 |
559 |
660 |
787 |
838 |
889 |
991 |
1092 |
1194 |
1397 |
L(RTJ) |
mm |
295 |
333 |
359 |
435 |
511 |
562 |
664 |
791 |
841 |
892 |
994 |
1095 |
1200 |
1407 |
d1 |
mm |
92 |
105 |
127 |
157 |
186 |
216 |
270 |
324 |
381 |
413 |
470 |
533 |
584 |
692 |
d2 |
mm |
127 |
149 |
168.5 |
216 |
267 |
292 |
349 |
432 |
489 |
527 |
603 |
654 |
724 |
838 |
D |
mm |
165 |
190 |
210 |
273 |
330 |
356 |
419 |
508 |
559 |
603 |
686 |
743 |
813 |
940 |
b |
mm |
26 |
29 |
32 |
38 |
45 |
48 |
56 |
64 |
67 |
70 |
77 |
83 |
89 |
102 |
n-Фd |
mm |
8-19 |
8-22 |
8-22 |
8-25 |
8-29 |
12-29 |
12-32 |
16-35 |
20-35 |
20-38 |
20-41 |
20-44 |
24-44 |
24-52 |
H |
mm |
444 |
500 |
558 |
665 |
760 |
868 |
1073 |
1263 |
1600 |
1705 |
1835 |
|
|
|
H1 |
mm |
|
|
585 |
695 |
790 |
900 |
1110 |
1300 |
1650 |
1750 |
1900 |
2020 |
2172 |
2650 |
W |
mm |
200 |
250 |
280 |
300 |
350 |
450 |
500 |
650 |
700 |
900 |
900 |
|
|
|
W1 |
mm |
|
|
310 |
310 |
310 |
310 |
310 |
460 |
460 |
460 |
460 |
600 |
600 |
600 |
Class900 Fugitive Emission Gate Valve
NPS |
in |
2 |
2 1/2 |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
14 |
16 |
18 |
20 |
24 |
d |
mm |
47 |
57 |
73 |
98 |
121 |
146 |
190 |
234 |
282 |
311 |
354 |
400 |
444 |
533 |
L(RF) |
mm |
368 |
419 |
381 |
457 |
559 |
610 |
737 |
838 |
965 |
1029 |
1130 |
1219 |
1321 |
1549 |
L(BW) |
mm |
368 |
419 |
381 |
457 |
559 |
610 |
737 |
838 |
965 |
1029 |
1130 |
1219 |
1321 |
1549 |
L(RTJ) |
mm |
371 |
422 |
384 |
460 |
562 |
613 |
740 |
841 |
968 |
1039 |
1140 |
1232 |
1334 |
1568 |
d1 |
mm |
92 |
105 |
127 |
157 |
186 |
216 |
270 |
324 |
381 |
413 |
470 |
533 |
584 |
692 |
d2 |
mm |
165 |
190.5 |
190.5 |
235 |
279.4 |
317.5 |
393.7 |
469.9 |
533.4 |
558.8 |
615.9 |
685.8 |
749.3 |
901.7 |
D |
mm |
216 |
244 |
241 |
292 |
349 |
381 |
470 |
545 |
610 |
640 |
705 |
785 |
855 |
1040 |
b |
mm |
38.5 |
41.5 |
38.5 |
44.5 |
51 |
56 |
64 |
70 |
79.5 |
86 |
89 |
102 |
108 |
140 |
n-Фd |
mm |
8-26 |
8-29 |
8-26 |
8-32 |
8-35 |
12-32 |
12-39 |
16-39 |
20-39 |
20-42 |
20-45 |
20-51 |
20-54 |
20-67 |
H |
mm |
500 |
550 |
610 |
702 |
850 |
980 |
1100 |
1320 |
1500 |
1900 |
2050 |
|
|
|
H1 |
mm |
|
|
660 |
750 |
900 |
1060 |
1140 |
1370 |
1560 |
1950 |
2100 |
2300 |
2450 |
2600 |
W |
mm |
280 |
280 |
300 |
350 |
400 |
500 |
650 |
700 |
900 |
900 |
900 |
|
|
|
W1 |
mm |
|
|
310 |
310 |
310 |
460 |
460 |
460 |
460 |
600 |
600 |
600 |
600 |
600 |
Class1500 Fugitive Emission Gate Valve
NPS |
in |
2 |
2 1/2 |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
14 |
16 |
d |
mm |
47 |
57 |
70 |
92 |
111 |
136 |
178 |
222 |
263 |
289 |
330 |
L(RF) |
mm |
368 |
419 |
470 |
546 |
673 |
705 |
832 |
991 |
1130 |
1257 |
1384 |
L(BW) |
mm |
368 |
419 |
470 |
546 |
673 |
705 |
832 |
991 |
1130 |
1257 |
1384 |
L(RTJ) |
mm |
371 |
422 |
473 |
549 |
676 |
711 |
841 |
1000 |
1146 |
1276 |
1407 |
d1 |
mm |
92 |
105 |
127 |
157 |
186 |
216 |
270 |
324 |
381 |
413 |
470 |
d2 |
mm |
165 |
190.5 |
203.2 |
241.3 |
292.1 |
317.5 |
393.7 |
482.6 |
571.5 |
635 |
704.8 |
D |
mm |
216 |
244 |
267 |
311 |
375 |
394 |
483 |
585 |
675 |
750 |
825 |
b |
mm |
38.5 |
41.5 |
48 |
54 |
73.5 |
83 |
92.9 |
108 |
124 |
133.5 |
146.5 |
n-Фd |
mm |
8-26 |
8-29 |
8-32 |
8-35 |
8-42 |
12-39 |
12-45 |
12-51 |
16-54 |
16-61 |
16-67 |
H |
mm |
510 |
560 |
620 |
728 |
870 |
1000 |
1130 |
1360 |
|
|
|
H1 |
mm |
|
|
670 |
770 |
920 |
1070 |
1180 |
1410 |
1620 |
2020 |
2180 |
W |
mm |
280 |
300 |
350 |
400 |
450 |
500 |
750 |
900 |
|
|
|
W1 |
mm |
|
|
310 |
310 |
310 |
460 |
460 |
600 |
600 |
600 |
600 |
Class2500 Fugitive Emission Gate Valve
NPS |
in |
2 |
2 1/2 |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
d |
mm |
38 |
47 |
57 |
73 |
92 |
111 |
146 |
184 |
219 |
L(RF) |
mm |
451 |
508 |
578 |
673 |
794 |
914 |
1022 |
1270 |
1422 |
L(BW) |
mm |
451 |
508 |
578 |
673 |
794 |
914 |
1022 |
1270 |
1422 |
L(RTJ) |
mm |
454 |
514 |
584 |
683 |
807 |
927 |
1038 |
1292 |
1445 |
d1 |
mm |
92 |
105 |
127 |
157 |
186 |
216 |
270 |
324 |
381 |
d2 |
mm |
171.4 |
196.8 |
228.6 |
273 |
323.8 |
368.3 |
438.1 |
539.7 |
619.1 |
D |
mm |
235 |
267 |
305 |
356 |
419 |
483 |
550 |
675 |
760 |
b |
mm |
51 |
57.5 |
67 |
76.5 |
92.5 |
108 |
127 |
165.5 |
184.5 |
n-Фd |
mm |
8-29 |
8-32 |
8-35 |
8-42 |
8-48 |
8-54 |
12-54 |
12-67 |
12-74 |
H |
mm |
530 |
580 |
650 |
750 |
900 |
1040 |
1150 |
1400 |
|
H1 |
mm |
580 |
630 |
700 |
800 |
960 |
1100 |
1200 |
1460 |
1660 |
W |
mm |
280 |
300 |
350 |
400 |
500 |
600 |
750 |
900 |
|
W1 |
mm |
310 |
310 |
310 |
310 |
460 |
460 |
460 |
600 |
600 |
API Trim NO. Table
No of internal parts |
Seat ring or body |
Gate、disc 、ball or body |
Stem |
No of internal parts |
Seat ring or body |
Gate、disc 、ball or body |
Stem |
|
01 |
13Cr |
13Cr |
13Cr |
31 |
STELLITE |
321SS |
321SS |
|
02 |
304SS |
304SS |
304SS |
32 |
STELLITE |
STELLITE |
321SS |
|
03 |
310SS |
310SS |
310SS |
33 |
347SS |
347SS |
347SS |
|
04 |
HARD 13Cr |
HARD 13Cr |
13Cr |
34 |
STELLITE |
347SS |
347SS |
|
05 |
STELLITE |
STELLITE |
13Cr |
35 |
NICKEL ALLOY |
13Cr |
13Cr |
|
06 |
Cu-Ni |
13Cr |
13Cr |
36 |
A105/PTFE |
A105 ENP |
A105 ENP |
|
07 |
13Cr |
HARD 13Cr |
13Cr |
37 |
A105/PTFE |
WCB ENP |
A105 ENP |
|
08 |
STELLITE |
13Cr |
13Cr |
38 |
13Cr/PTFE |
13Cr |
13Cr |
|
09 |
Cu-Ni |
Cu-Ni |
Cu-Ni |
39 |
304SS/PTFE |
304SS |
304SS |
|
10 |
316SS |
316SS |
316SS |
40 |
316SS/PTFE |
316SS |
316SS |
|
11 |
Cu-Ni |
STELLITE |
Cu-Ni |
41 |
A105/RPTFE |
A105 ENP |
A105 ENP |
|
12 |
STELLITE |
316SS |
316SS |
42 |
A105/RPTFE |
WCB ENP |
A105 ENP |
|
13 |
ALLOY 20 |
ALLOY 20 |
ALLOY 20 |
43 |
13Cr/RPTFE |
13Cr |
13Cr |
|
14 |
STELLITE |
ALLOY 20 |
ALLOY 20 |
44 |
304SS/RPTFE |
304SS |
304SS |
|
15 |
STELLITE |
STELLITE |
304SS |
45 |
316SS/RPTFE |
316SS |
316SS |
|
16 |
STELLITE |
STELLITE |
316SS |
46 |
A105/NYLON |
A105 ENP |
A105 ENP |
|
17 |
STELLITE |
STELLITE |
347SS |
47 |
A105/NYLON |
WCB ENP |
A105 ENP |
|
18 |
STELLITE |
STELLITE |
ALLOY 20 |
48 |
A105/NYLON |
304SS |
304SS |
|
19 |
MONEL |
MONEL |
MONEL |
49 |
A105/NYLON |
316SS |
316SS |
|
20 |
BRONZE |
BRONZE |
13Cr |
50 |
13Cr/NYLON |
13Cr |
13Cr |
|
21 |
HASTELLOY B |
HASTELLOY B |
HASTELLOY B |
51 |
304SS/NYLON |
304SS |
304SS |
|
22 |
|
HASTELLOY C |
HASTELLOY C |
52 |
316SS/NYLON |
316SS |
316SS |
|
23 |
STELLITE |
304SS |
304SS |
53 |
A105/PEEK |
A105 ENP |
A105 ENP |
|
24 |
304LSS |
304LSS |
304LSS |
54 |
A105/PEEK |
WCB ENP |
A105 ENP |
|
25 |
STELLITE |
304LSS |
304LSS |
55 |
13Cr/PEEK |
13Cr |
13Cr |
|
26 |
STELLITE |
STELLITE |
304LSS |
56 |
304SS/PEEK |
304SS |
304SS |
|
27 |
316LSS |
316LSS |
316LSS |
57 |
316SS/PEEK |
316SS |
316SS |
|
28 |
STELLITE |
316LSS |
316LSS |
|
|
|
|
|
29 |
STELLITE |
STELLITE |
316LSS |
|
|
|
||
30 |
321SS |
321SS |
321SS |
|
|
|
|
Note:please indicate it directly in the order for the internal part’smaterial uncovered in the table
¿Tienes alguna pregunta? Todo lo que necesitas saber sobre el producto y cómo funciona.
Good News!
Sedelon has produced a big size gate valve for 36 inch 600LB this May. This big-size valve was exported to Iran. This Iran customer has done business with US from 2007. I believe this order for the big-size gate valve will take our business relationship to a higher position.
On Apr.28th, 2012, our manager Mr. Sam visited Korea customer (GOC. chemical company).That was the first time to have an inspection after the valves installed. The whole project adopted our products, such as gate valve, globe valve, check valve and regulating valve etc. The project will be completed in the middle of next month.
Congratulations! Sedelon ® Gate Valve has obtained Fugitive Emission certificates. Perfect design, Special facilities and excellenttechnique. Our products have been sold to Taiwan, America, Germany…ect,.
Fugitive Emission Valves are thosevalves which bleed only a small amount of leakage to the external environment.In some European countries, there are customized companies to provide Fugitive Emission Testing Service for the local manufactures and end users.
At present, theFugitive Emission Test Standards of International authority are the following three:EPAmethod21, ISO15848 and SHELLMESCSPE77/312.Among them, EPAmethod21 had detaileddescriptions of rules for the Fugitive Emission Testing Methods. ISO15848 and SHELLMESCSPE77/312 evaluate the performance of the valves in three aspects, such as Tightness Class, Endurance Class and Temperature Class. The classes are evaluated as A, B or C.
Bellows seal gate valve - Sedelon Valve
Sedelon Seal Face Material Selection Factors
Sedelon valve knowledge science - common failures and preventive measures of valves
Sedelon Valve Knowledge Science - Insulated Valve
API600 Standard Valves Seating Surface Material Classification and Characteristics
Types of valve gaskets
Differences between Rising Stem Gate Valves and Non-Rising Stem Gate Valves
Difference Between Limit Switches and Proximity Switches
In order to improve our production effectiveness and speed up the delivery time, we Sedelon built a new extra factory, it covers an area of 15000 square meters. It has already been put into production successfully this year!
We use cookies to enhance your browsing experience, serve personalized ads or content, and analyze our traffic. By clicking "Accept All", you consent to our use of cookies.